GB/T 16292-2025: standard information and instrument checks
Test method for airborne particles in clean room (zone) of the pharmaceutical industry has an implementation date of 1 November 2026. This page brings together the official information, product documentation and boundaries for technical review.
NovoClean airborne particle counters
The NovoClean 0.3 μm and 0.5 μm airborne particle counter ranges meet the relevant requirements for particle counters in GB/T 16292-2025.
For use, follow the standard’s requirements for calibration with standard particles and a valid calibration certificate. Calibration frequency and methods follow GB/T 29024.4 or currently recognized provisions in the relevant national metrology specifications. These instrument-use requirements are separate from ISO 9001 quality management system certification.
- Standard
- GB/T 16292-2025
- Publication date
- 2025-10-05
- Implementation date
- 2026-11-01
- Issuing authorities
- State Administration for Market Regulation and Standardization Administration of China
Start with the official document
The official information page confirms the title and dates. This page does not reproduce or interpret the full standard, or claim specific changes to tubing length, sample volume or acceptance methods. Check the official text and approved procedure.
Check the delivered configuration
Review the actual model, flow rate, particle-size channels, calibration status, sampling accessories and instructions. A model suffix or an isolated feature does not establish suitability for a project.
Separate features from verification
Permissions, audit trails and data outputs are product features. Confirm the events, fields and configuration against the delivered software version and technical checklist. Test results require records and review.
Keep the scope clear
This standard concerns airborne-particle testing, not microbial air samplers. Conformity with the relevant instrument requirements does not mean every organization must replace its instruments. Site testing follows applicable requirements and the approved procedure.
Product facts and documentation
- NW-3100 — Fixed 100 L/min, starting at 0.3 μm, eight channels; see the model page for permissions and audit-trail scope.
- Portable particle counters — Compare model-specific flow rates, detection thresholds and documentation.
- Product documents and PDFs — Check configuration against the model documents, contract and technical checklist; documents do not replace project verification.
- ISO 9001 quality management system certificate — Scope: R&D and sales of environmental monitoring instruments. It is not certification of a product to GB/T 16292-2025.
This page provides official information, the manufacturer’s product statement and documentation links, without reproducing the standard. Suitability depends on the intended task, configuration, calibration and verification records.